CATEGORII DOCUMENTE |
Bulgara | Ceha slovaca | Croata | Engleza | Estona | Finlandeza | Franceza |
Germana | Italiana | Letona | Lituaniana | Maghiara | Olandeza | Poloneza |
Sarba | Slovena | Spaniola | Suedeza | Turca | Ucraineana |
DOCUMENTE SIMILARE |
|
Calcul des éléments simples en bois soumises aux solicitations simples:
Caractéristiques de la poutre à treillis :
D = 9 m
h = 2.25 m
t = 4 m
Charge Permanente
ga = 55 daN/m2 – poids propre de la toiture + poids propre des éléments
gz = 90 daN/m2
n = 1.2
CzIII=1.25
pzC = ce *cz
*gz*γF ; ce = 0.8 ; γF
= γA – 0.4*ga/( ce* gz) =
1.694 ; γA = 2 .
gac = ga*n = 55*1.2 = 66 daN/m2 gac = ga*n*t = 55*1.2*4 =264 daN/ml
pzIC = = ce *czI *gz*γF = 122 daN/ m2 pzIC = = ce *czI *gz*γF*t = 488 daN/ m
pzIIC = = ce *czI *gz*γF = 91.5 daN/ m2 pzIIC = = ce *czI *gz*γF*t = 366 daN/ m
pzIIIC = = ce *czI *gz*γF = 152.5 daN/ m2 pzIIIC = = ce *czI *gz*γF*t = 610 daN/ m
Xeffectif≤Xcapable
Teffectif =effort maximal dans la semelle inférieure
Tr = Rcalcult x As x mlt
mlt = coefficient dependant du traitement contre l’action des insectes et des champignons
mlt = 0.9
Rct = Rnt x mnt x mdt x γt =14.4x1x0.93x1.2 = 16.07 N/mm2
Rnt = 14.4 N/mm2 pour un bois de la première classe de qualité, sans défaults
mnt = coefficient d’humidité =1 pour la première classe d’exploitation
mdt = (0.9p +0.95z)/(p+z) = 0.93
γt = 1.2
As = Tef/( Rctx mlt) = 3660.976x1.5x10/14.463 = 3796.9 mm2 =38 cm2
Section choisie : 15x15 Aeff=225cm2
Ceffectif≤ Cr
Cr = RccII x Ac x mct x γc
Ac = Ceff/( RccIIxmct x γc)=4190.944x10x1.68/1.927=366cm2
Section choisie : 15x25 Aeff=375cm2
Ac = D1eff/( RccIIxmct x γc)=818.376x10x1.68/1.237=112cm2
Ac = D2eff/( RccIIxmct x γc)=1035.048x10x2.12/1.237=178cm2
Section choisie : 10x19 Aeff=190cm2
A1nec = N1xkef/Ra=0
A2nec = N2xkef/Ra=366x1.25x10/210 =21.78 mm2=0.21cm2
A3nec = N3xkef/Ra=1464x1.25x10/210 = 87.14mm2=0.87cm2
Section choisie : Φ12=1.13cm2
Efforts dans les barres de la ferme :
Barre |
Type |
1daN/m -s |
1daN/m -d |
1daN/m-m |
366daN/m -s |
610daN/m -d |
488daN/m-m |
Semelle | |||||||
superieure | |||||||
| |||||||
Semelle | |||||||
inferieure | |||||||
Diagonalles | |||||||
Montants | |||||||
Joint du charpentier :
Noeud d’appui:
hc=max(h/3)=4cm
lp≥10hc=40cm; lp≥2h=30cm; lp≥20cm; lp=40cm
Capacité portante à ecrasement du seuil simple
Nr=(CrxQr)/(Crxsin2α+Qrxcos2α)=(233x110.38)/(233.1x0.21+110.38x0.79)=188.93N
Cr=RccIIxApIIxmT=9.96x29x0.9=233.1N
Qr=Rcc┴xAp┴xmTxmr=2.19x35x0.9x1.6=110.38N
Capacité portante à cisaillement du seuil simple :
Fr = RcfIIxAfxmT/mf = 1.464x60000x0.9/1=79.056kN
Af = bxlf=150x400=60000mm2
RcfII=(RnfIIxmdfIIxmn)/ γfII=3x(0.55p+0.65z)x1/(p+z)x1.25=1.464N/mm2
Vérifications:
Ecrasement: Nr ≥Nc
Cisaillement: Fr≥Nc1
Politica de confidentialitate | Termeni si conditii de utilizare |
Vizualizari: 831
Importanta:
Termeni si conditii de utilizare | Contact
© SCRIGROUP 2024 . All rights reserved